We ship nationwide. 30-day return policy. Free standard shipping on all orders.

    • No products in the cart.
Sale

Hantek DSO2000 Series

26,000.0034,000.00

Cost-effective economy oscilloscope, 150MHz Bandwidth, 1GSa/s, 8M memory depth; with 1CH 25MHz waveform generator, support arbitrary waveform output; 14 kinds of trigger modes, standard with 5 kinds of serial protocol triggers and decodes; 32 kinds of auto measurements with statistics; 3-digit digital voltage meter and 6-digit hardware frequency indicator functions; 2 sets of DVM; Abundant SCPI remote command control. It is a useful commissioning instrument for various fields such as communication, aerospace, national defense, embedded systems, computers, research and education.

Clear

Feature:

  1.  2 channels which are respectively controlled by independent knobs
  2. 100 MHZ and 150MHZ analog channel bandwidth
  3. Sampling rate up to 1 GSa/s
  4. 8M memory depth
  5. Vertical range 2mV/div ~ 10V/div
  6. Built-in 1 CH 25MHz waveform generator (DSO2D10, DSO2D15)
  7. Vertical resolution: 8bit
  8. Trigger: Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC
  9. BUS decode and protocol analysis: RS232/UART, I2C, SPI, CAN, LIN
  10. Can save multiple data formats, such as settings, waveforms, reference waveforms, CSV, pictures
  11. A 3-digit digital voltage meter and a 6-digit hardware frequency indicator
  12. 32 kinds of auto measurements with statistics, real-time statistics of maximum, minimum, standard deviation and etc.
  13. 2 sets of digital voltmeters
  14. Support threshold testing, free measurements within the screen
  15. Abundant SCPI remote command control
  16. USB Host/Device.

 

Model

DSO2D15, DSO2D10, DSO2C15, DSO2C10

Parameters

Model DSO2D15 DSO2D10 DSO2C15 DSO2C10
Bandwidth 150MHz 100MHz 150MHz 100MHz
Oscilloscope channels 2CH 2CH 2CH 2CH
Waveform generator 1CH 1CH  –  –
Oscilloscope
Sample rate 1GSa/s
(single channel) 500MSa/s (two channels)
Acquisition
Normal Sample
data
Peak-to-peak value Display
high frequency and random burr
Average Average
waveform, times:  4, 8, 16, 32, 64, 128
High resolution Up to
12bit
Input
Input coupling DC,
AC, GND
Input impedance 1MΩ±2%
‖20pF±3pF
Probe attenuation  factor 1X,
10X, 100X, 1000X
Voltage rating 300V
CAT II
Maximum input voltage 300VRMS
(10X)
Horizontal
Waveform interpolation (sin
x)/x
Maximum record length Single
channel maximum 8M
Two channels maximum 4M
Horizontal scale range 2ns/div~100s/div
1, 2, 5 step by step
Time base mode Y-T,
X-Y, Roll
Zero offset ±0.5
div×minimum time base gear
Sample Rate and Delay Time Accuracy ±25ppm
Delta Time Measurement Accuracy (Full
Bandwidth)Sample Rate and Delay Time Accuracy
single-shot,
Normal mode   ±1
sample interval+100ppm×reading+0.6ns
16 times
averages ±
1
sample interval+100ppm×reading+0.4ns
Sample interval=sec/div÷200
Sample Rate and Delay Time Accuracy ±50ppm(at
any interval greater than 1ms)
Vertical
Model DSO2D15 DSO2D10 DSO2C15 DSO2C10
Bandwidth 150MHz 100MHz 150MHz 100MHz
Rising time in BNC position (typical) 2.4ns 3.5ns 2.4ns 3.5ns
Vertical resolution 8
bits resolution, each channel samples simultaneously
Vertical sensitivity 2mV/div
to 10V/div
Offset range 200mV/div, ±1V;
200mV/div
±50V
Mathematical operation +, -,
×, ÷, FFT
FFT Window:
Rectangle, Hanning, Hamming, Blackman, Bartlett, Flattop
Bandwidth Limit 20MHz
Bass response(-3db) In
BNC position ≤ 10Hz
Vertical gain accuracy In
”normal”  or ”average” acquisition mode, the accuracy of
10V/div to 10mV/div is ±3%;
In ”normal” or ”average” acquisition mode, the accuracy
of 5mV/div to 2mV/div is ±4%
Note:
Bandwidth reduced to 6MHz when using a 1X probe
Trigger
Trigger type Edge, Pulse
width, Video, Slope, Overtime, Window, Pattern, Interval,
Under Amp, UART, LIN, CAN, SPI, IIC
Trigger level range ±5
divisions from the center of the screen
Trigger mode Auto,
Normal, single
Level CH1~CH2 ±4
divisions from the center of the screen
EXT(Only With AWG Model) 0~3.3V
Holdoff range 8ns~10s
Trigger level accuracy CH1~CH2 0.2
div×volts/div within ±4 divisions from the center of the screen
EXT(Only With AWG Model) ±(Set
value× 6%+40mV)
Edge trigger Slope Rising
edge, falling edge, rising or falling edge
Signal source CH1, CH2, EXT(Only With AWG Model)
Pulse width trigger Polarity Positive
polarity, negative polarity
Condition(When) <,
>, !=, =
Signal source CH1~CH2,
Pulse width range 8ns ~
10s
Accuracy 8ns
Video trigger Signal
standard
NTSC,
PAL
Signal source CH1~CH2
Synchronization Scanning
line, line number, odd field, even field, all field
Slope trigger Slope rising,
falling
Condition(When) <,
>, !=,  =
Signal source CH1 ~
CH2
Time range 8ns ~
10s
Accuracy 8ns
Overtime trigger Signal
source
CH1~CH2,
Polarity Positive
polarity, negative polarity
Time range 8ns ~
10s
Accuracy 8ns
Window trigger Signal
source
CH1~CH2
Pattern trigger Pattern 0:
low level; 1: high level; X: ignore
Level(signal source) CH1~CH2
Interval trigger Slope rising,
falling
Condition(When) <,
>,  !=,  =
Signal source CH1~CH2
Time range 8ns ~
10s
Accuracy 8ns
Under Amp trigger Polarity Positive
polarity, negative polarity
Condition(When) <,
>, !=, =
Signal source CH1~CH2
Time range 8ns ~
10s
Accuracy 8ns
UART trigger Condition(When) Start,
Stop, data, Parity ERR, COM ERR
Signal source(RX/TX) CH1~CH2
Data format Hex
(hexadecimal)
Data length 1
byte
Data bit width 5
bit, 6 bit, 7 bit, 8 bit
Odd-even check none,
odd, even
Idle level high,
low
Baud rate (optional) 110 / 300 / 600 / 1200 / 2400 / 4800 / 9600 / 14400 / 19200 / 38400 / 57600 / 115200 / 230400 / 380400 / 460400
bit/s
Baud rate(user-defined) 300bit/s~334000bit/s
LIN trigger Condition(When) Interval
field, synchronization field, ID field, synchronization error, identifier, ID
and data
Signal source CH1~CH2
Data format Hex
(hexadecimal)
Baud rate (optional) 110 / 300 / 600 / 1200 / 2400 / 4800 / 9600 / 14400 / 19200 / 38400 / 57600 / 115200 / 230400 / 380400 / 460400
bit/s
Baud rate(user-defined) 300bit/s~334000bit/s
CAN trigger Condition(When) Start
bit, remote frame ID, data frame ID, frame ID, data frame data, error frame,
all errors, ACK Error, overload frame
Signal source CH1~CH2
Data format Hex
(hexadecimal)
Baud rate (optional) 10000,
20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000,
1000000
Baud rate(user-defined) 5kbit/s~1Mbit/s
SPI trigger Signal
source
CH1~CH2
Data format Hex (hexadecimal)
Data bit width 4, 8,
16, 24, 32
IIC trigger Signal
source (SDA/SCL)
CH1~CH2
Data format Hex (hexadecimal)
Data index 0~7
When(condition) Start
bit, stop bit, No Ack, address, restart, address and data
Measurement
Cursor Voltage
difference between cursors △V
Time difference between cursors △T
Reciprocal of △T, in Hertz (1/△T)
Auto measurement frequency,
period, mean, peak-to-peak, RMS, minimum, mixmum, rising time, falling time,
+ width, – width, base, top, middle, amplitude, overshoot, preshoot, rising
edge phase difference, falling edge phase difference, + duty, – duty, period
mean, PRMS, FOVshoot, ROVshoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
DVM Data
source
CH1,
CH2
Measurement type DC
RMS
AC RMS
DC
Frequency meter hardware
6 bits frequency meter
Arbitrary
waveform generator
Channel 1
Sample rate 200MSa/s
Vertical resolution 12
bits
Maximum frequency 25
MHz
Standard waveforms sine,
square, ramp,Exp, noise, DC
Arbitrary waveform Arb1,
Arb2, Arb3, Arb4
Sin Frequency
range
0.1Hz~25MHz
Square/pulse Frequency
range
0.1Hz~10MHz
Triangular wave Frequency
range
0.1Hz~1MHz
Sampling wave Frequency
range
0.1Hz~1MHz
Index Frequency
range
0.1Hz~5MHz
Noise
Arb1 Frequency
range
0.1
Hz to 10 MHz
Arb2 Frequency
range
0.1
Hz to 10 MHz
Arb3 Frequency
range
0.1
Hz to 10 MHz
Arb4 Frequency
range
0.1
Hz to 10 MHz
Waveform length 4KSa
Frequency Accuracy 100
ppm (<10 kHz) 50 ppm (>10 kHz)
Resolution 0.1
Hz or 4 bits,take the greater one
Amplitude Output
range
10mV~7Vp-p
(high impedance)
5mV~3.5Vp-p (50Ω)
DC offset Range ±3.5
V, high impedance
±1.75 V, 50 Ω
Resolution 100
μV or 3 bits, take the greater one
Accuracy 2% (1
kHz)
Output impedance 50 Ω
General
specifications
Display Display
type
7” diagonal TFT liquid
crystal
Display resolution 800
(horizontal)*480 (vertical) pixels
Display colour 16
million colours (24 bits true colour)
Persistence time minimum, 1
s, 5 s, 10 s, 30 s, infinite
Display type dot,
vector
Display brightness adjustable
Grid type adjustable
Grid brightness adjustable
Interface Standard
interface
USB
Host,USB Device
General specifications Probe
compensator output
Output voltage, typical about
2Vpp input ≥1MΩ load
Frequency, typical 1kHz
Power supply 100-120VACRMS(±10%), 45Hzto 440Hz,
CATⅡ
120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
Power consumption <30W
Fuse T,
3.15A, 250V, 5x20mm
Operating temperature 0~50
°C (32~122 °F)
Storage temperature -40~+71
°C (-40~159.8 °F)
Humidity ≤+104℉(≤+40°C):
≤90% relative humidity
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity
Altitude Operating
and nonoperating
3,
000m (10, 000 feet)
Mechanical shock Random
vibration
0.31
g RMS from
50Hz to 500Hz,
10 minutes on each axis
Nonoperating 2.46g RMS from 5Hz
to 500Hz,
10 minutes on each axis
Operating 50g,
11ms, half-sine wave
Mechanical Size 318 x
110 x 150mm (length x width x height)
Weight 1900g

Reviews

There are no reviews yet.

Be the first to review “Hantek DSO2000 Series”